Physical Characteristics
|
Certifications
|
Conductor: 24 AWG (0.51mm) Solid Bare Copper
|
ISO9001: 2008, ISO14001: 2004, OHSAS 18001
|
Insulation: 0.9mm HDPE
|
ANSI/ TIA 568-C.2
|
Conductor Color Code:
|
UL listed Type: CMR (UL 1666), CM(UL 1681),NEC 760
|
Pair 1: Blue – White/Blue Pair 2: Orange – White/Orange
|
UL 444
|
Pair 3: Green – White/Green Pair 4: Brown – White/Brown
|
RoHS / REACH Compliant
|
Overall Shield: Aluminum/Polyester 100%coverage
|
|
Drain Wire: 24 AWG stranded tinned copper
|
Electrical Characteristics
|
Rip Cord: Applied longitudinally under jacket
|
Max Capacitance (nF/100m @ 1 kHz): 5.6
|
Jacket: PVC
|
Max DC Resistance (Ω/100m @ 68℉): 9.38
|
Nominal Cable Diameter: 6.0mm
|
Max Delay Skew (ns/100m): 45
|
Nominal Cable Net Weight (1000 ft): 12kg
|
Nom Velocity of Propagation (%): 70
|
Minimum Bend Radius : 9mm
|
Characteristic Impedance (Ω@ 1- 100 MHZ): 100±15
|
Maximum Pulling Force : 18kg
|
|
Temperature Rating :
|
|
Installation: 0℃ to + 60℃
|
|
Storage & Operation: -20℃ to + 75℃
|
|